Zhejiang Delage Machinery Compressor Co.,Ltd

enLanguage

Attention To The Operation Of Screw Compressors

Sep 17, 2023 Leave a message

1. Before the start of operation
1. Check to confirm whether the valves in each part are in the correct position.
2. Check that all guards and safety accessories are in good condition.
3. Check that the lubricating oil level meets the standard.
II. Operation steps
1. First press the air dryer "ON" button, and then let the air dryer run for more than 5 minutes. Observe whether the dryer is running normally and smoothly.
2. Press the air compressor "start" button (or "*" key).
3. Slowly open the exhaust valve until it is fully open.
3. Shutdown
1. Press the air compressor "Stop" button (or "O" key).
2. Press the "OFF" button of the air dryer.
3. Close the exhaust valve.
IV. Safety and Precautions
1. When the ambient temperature is close to 30 degrees Celsius, the exhaust fan should be turned on to reduce the indoor temperature.
2. When the ambient temperature exceeds 30 degrees Celsius, the induced draft fan should be turned on to reduce the indoor temperature.
3. When the indoor noise is greater than 90dB (A), wear ear protection earcups.