1. Check the empty filter element and coolant level;
2. Check whether there is leakage of the hose and all pipe joints;
3. Check the records, if the consumable parts have reached the replacement cycle, they must be stopped for replacement;
4. Check the record, when the exhaust temperature of the host reaches or is close to 98 °C, the oil cooler must be cleaned;
5. Check the records, if it is found that the pressure difference of the separator reaches more than 0.6BAR (limit 1BAR) or the pressure difference begins to decline, the separation core should be stopped and replaced;
6. Check the condensate discharge, if it is found that the discharge is too small or there is no condensate discharge, the water separator must be shut down to clean it.